COMMERCIAL GENERATORS

Losing power for even a few hours can mean thousands of dollars in lost revenue to your business. Security systems go down, refrigerated goods spoil, and customers are turned away.

During a power outage is not the time to wish you had a generator. A standby Kohler commercial generator keeps your power on and your business open during an outage.

When utility power is interrupted, the ATS signals the generator to start and then quickly transfers the electrical loads from the failed utility to the generator. When utility power is restored, the ATS transfers the electrical loads back to the utility and shuts down the generator. It's installed outside your business (like an AC unit) and comes on automatically — whether you're open or closed. All within seconds of a power outage.

Plus commercial generators run on propane or natural gas, so there's no refueling.

Model Number 24RCL 30RCL 38RCLB 48RCL 60RCL
Rated Power LP/NG (kW) 24/21 30/30 38/38 48/48 59/57
Voltage @ 60 Hz 120/240 120/240 120/240 120/240 120/240
Phase Single/Three Single/Three Single/Three Single/Three Single/Three
Amps LPG/NG @ 240 V 100/87 125/125 158/158 200/200 246/238
Automatic Transfer Switch and Load Control Module (LCM) Compatibility RDT, RXT, LCM, RSB
Engine/Alternator RPM 1800 1800 1800 1800 1800
Engine 2.2 L 2.2 L 4.3 L 5.0 L 5.7 L
Kohler KG2204 Kohler KG2204 Kohler KG2204 General Motors Vortec General Motors Vortec
In-line 4 In-line 4 V-6 V-8 V-8
Fuel LPG/Natural Gas LPG/Natural Gas LPG/Natural Gas LPG/Natural Gas LPG/Natural Gas
Engine Cooling Liquid Liquid Liquid Liquid Liquid
Enclosure Corrosion-Resistant Aluminum Corrosion-Resistant Aluminum Corrosion-Resistant Aluminum Corrosion-Resistant Aluminum Corrosion-Resistant Aluminum
Sound Output dBA at 23 Ft 61* 61* 61* 61* 61*
Dimensions (L x W x H) In 74 x 32.9 x 45.1 74 x 32.9 x 45.1 90 x 33.5 x 45.1 90 x 33.5 x 45.1 89.8 x 32.9 x 45.2
Digital Voltage Regulation +/- 1.0% +/- 1.0% +/- 1.0% +/- 1.0% +/- 1.0%
Specification Sheet 24RCL 30RCL 38RCLB 48RCL 60RCL
RATINGS: Standby ratings apply to installations served by a reliable utility source. All single-phase units are rated at 1.0 power factor. The standby rating is applicable to variable loads with an average load factor of 80% for the duration of the power outage. No overload capacity is specified at this rating. Ratings are in accordance with ISO-3046/1, BS5514, AS2789 and DIN 6271. GENERAL GUIDELINES FOR DERATION: Altitude: Derate 4% per 305 m (1000 ft) elevation above 153 m (500 ft). Temperature: Derate 2% per 5.5˚C (10˚F) temperature increase above 16˚C (60˚F).
*Measured at 23 feet with no load.